Technical information

Airflow [m3/h] 20-60
Heat recovery* [%] up to 95
Returning energy** [%] up to 70
Connection voltage [V] 230/24
Power required [W] up to 50
Noise*** [dB] up to 35
Dimensions [mm] 1510 / 300 / 230
Filters PM 2.5 (F7)
PM 10 (G4)
Outdoor temperature range [°C] from -25 up to 50
Control Remote / WiFi** / ModBus**
Preheating the air** [W] 600
Sensors Temperature, Moisture, CO2**, VOC**, Radon**

* At maximum airflow with F7 filter according to EN 308
** On reques
*** At 8 dB of damping in the room

Clean air

MIKrovent Office is serially fitted with the F7 in G4 filters.

The inlet air filter PM 2.5 (F7) is extremely sensitive and can remove small fine air particles measuring 2.5 μm or less. In order to successfully retain small air particles, the filter must be made of special non-washable materials.

The outlet air filter PM 10 (G4) is a washable filter, preventing the entry of hard particles measuring from 2.5 μm to 10 μm.

Breathe better air. Choose MIKrovent ventilation.

Inlet air filter PM 2.5 (F7)

Outlet air filter PM 10 (G4)

Control

You control MIKrovent Office by a user-friendly remote control which can also be used to set its weekly programmer.

Breathe better air. Choose MIKrovent ventilation.

Installation location

MIKrovent Office can be installed on a wall (be careful not to damage in-wall wiring).

Breathe better air. Choose MIKrovent ventilation.

Mounting on the wall

Operation

Inlet air enters the MIKrovent Office ventilation unit through the grille and duct, whereas the grille and the duct are separated by an intermediate distribution plate, preventing the mixing of inlet and outlet air. The inlet and outlet air travel along two separate chambers. Both air flows meet in the heat exchanger, where the outlet air emits energy and heat to the inlet air (either heating or cooling the air).

MIKrovent Office is serially fitted with humidity and temperature sensors and can operate in 4 different modes (air supply, air discharge, automatic and manual mode) and at 5 intensity levels. To ensure optimum conditions and ensure a high level of living comfort, we recommend that you use automatic mode.

MIKrovent Office operates in the temperature range from -25°C to +50°C. The unit operates at all temperature and humidity conditions without interruptions.

Breathe better air. Choose MIKrovent ventilation.

Appearance

MIKrovent Office comes in white, but you can choose from various predesigned casing templates or completely personalize the unit’s look with a photo of your choice.

The outer grille is made of aluminum and coloured in white. Upon request it can also match the color of your façade according to the RAL scale.

Breathe better air. Choose MIKrovent ventilation.

Maintenance

MIKrovent Office is easy to maintain. In order for the ventilation unit to operate without interruptions and supply clean air into the room, you need to make sure the filters are clean.

The inlet air filter should be replaced depending on air pollution, however, at least once a year.

The outlet air filter is washable and we recommend that you wash it several times per year.

Breathe better air. Choose MIKrovent ventilation.

Scope of delivery

When purchasing MIKrovent Office the customer receives the ventilation unit with serially fitted temperature and humidity sensors, a set of filters (outlet and inlet), a remote control, and all required installation materials, including pipes/ducts and polystyrene. Consumables (such as polyurethane foam) are not included and must be supplied by the customer.

Breathe better air. Choose MIKrovent ventilation.

Installation

The ventilation unit can be installed by MIK installers at a surcharge. Bore drilling service and preparatory construction works can also be provided by MIK at a surcharge.

Before installing MIKrovent Office, a ɸ200 mm bore needs to be drilled to insert the polystyrene cartridge body, which is cut to the length of the bore and sealed with polyurethane foam. A metal mounting plate is mounted over the bore with 6 wall-fixing screws. The interior of the MIKrovent Office ventilation unit and outer casing are mounted onto the mounting plate with a clip-on system. A designer outer grille covering the bore is mounted to the outside of the building with four screws. The MIKrovent unit must be connected to a 230 V/50 Hz power source via the supplied triple cable.

The installation does not include installation of wiring and cables, which must be provided for by the customer prior to installer’s arrival.

Breathe better air. Choose MIKrovent ventilation.

Do you have sleeping problems or suffer from insomnia?
Breathe better air. Choose MIKrovent ventilation.

Related products

MIKrovent Home30

MIKrovent Home30 is the first unit from the family of MIKrovent local ventilation units. It is intended for ventilation of individual rooms up to 20 – 25 m², e.g. children’s rooms, bedrooms and similar rooms, occupied by one or two persons.

MIKrovent Professional120

MIKrovent Professional120 is intended for ventilating larger spaces, occupied by more persons (schools, kindergartens, playrooms, dining rooms, halls, meeting rooms, waiting rooms, etc.) in size of up to 120 m².

Do you have sleeping problems or suffer from insomnia?
Breathe better air. Choose MIKrovent ventilation.